Application Specifications for Flooring Using compressed
Hardisheet
Insure all sheets are fixed according to MFC instructions and
that stainless steel counter sunk screws are used. 3 -6 mm
expansion joints should be left to allow for Deckseal JC
Apply 2 coats of Aquepoxy A & B mixed equal parts (1 to 1)
by volume. Up to 25% water may be added to the first coat of
Aquepoxy a & B mixed to assist wetting out the substrate
especially in hot conditions. Allow this final coat to dry 2
- 4 hours. In some instances a third coat may be neccessary
to level joints.
Apply 4 coats of CTEM Deckcoat to total area. Use a
Blacktex Stipple roller to provide slight embossed texture.
This will also assist with Anti Skid properties. if a
smoother top coat finish is required add 10 - 15% water to 4th coat
only.
CTEM Deckcoat should definitely not be used in temperatures
below 15'C and should only be applied in hot summer months.
It is not recommended in cold winter as through dry is considerably
inhibited. if application temperatures are below 20'C then
apply more coats at thinner film builds to allow complete drying
between coats.
Apply at the rate of 1/2 per m2. this should provide a
film thickness of approximately 600 microns DFT. clean up
before dry use with clean water. Contact Special finishes ltd
before any application to unfamiliar substrates.
Warranty / Liability
Special Finishes (NZ) Ltd provides all the enclosed information in good faith but without warrantee and is to assist your application. However the use of this product being used is beyond their control. The manufacturers can accept no responsibility whatsoever for any damage or failure arising from its application or use. It is totally the responsibility of the user to insure that the product is suitable for its intended use.