Armepoxy is a two pack high build Epoxy coating. It is
modified with a special flow promoter to ease application and does
not contain solvents. This low toxic no fumes, makes Armepoxy
an ideal system to coat inside floors in factories, freezing works
and in confined places.
Low toxic, no solvent fumes, high chemcial resistance, abrasion
resistant, hard durable finish. It has excellent adhesion to
concrete, steel, timber etc., and will cure around 3'C.
Armepoxy protective coatins are used extensively in multi-colour
seamless flake flooring systems, multi-chip coatings, swimming
pools, steelwork, food processing areas, meat and dairy industries,
garages, workshops, chemical and oil industry factories, and all
types of industrial and commercial concrete floors.
It is particularly recommended where high performance, hard
durable chemical resistant coating is required.
Full Gloss / Anti-skid
Roller, Bursh or Airless spray.
| Part 'A' |
3 litres in a 4-litre tin |
| Part 'B' |
1 litre in a 1 litre tin |
150'C
Not Applicable
Flammable. Avoid contact with skin. Remove from skin
immediately (using soap and water. Use suitable
respirator. Water protective clothing, including face
protection. Provide adequate ventilation in confined
areas. Keep away from children.
Volume 'A' and 'B - 3 to 1
Important to mix accurately, 3 parts 'A' to 1 part 'B' Hardener
by volume.
Stir each part thoroughly. then add 'A' and 'B' together
and stir until mix is homogenous. Leave to stand for 3
minutes. Then stir and use.
Mix to 1 litre "A' resin, add 340 mls of Hardener 'B'
Do not thin topcoats as colour floatation may occur.
at 25'c, 50% relative humidity - 1 hour
Only mix sufficient Armepoxy that can be used within 30 minutes
- as large mixed quantities will generate Exothermic Reaction and
subsequent loss of material.
25'C, 50% RH
| Touch Dry |
4 Hours |
| Hard Dry |
8 Hours |
| Recoat Minimum |
8 Hours |
| Reacoat Maximum |
24 Hours |
| Wet |
100 microns |
| Dry |
100 microns |
2 coats unthinned - 3 coats on porous rough surfaces
| Smooth Surfaces |
6 m2 per litre per coat |
Minimum of 2 coats required
= 3m2 per litre coverage
|
| Rough Surfaces |
4 m2 per litre per coat |
Minimum of 2 coats required
= 2m2 per litre coverage
|
Armepoxy Solvent, Special Finishes' All Purpose thinners, UC500
Reducer.
Observe new Occupational Safety & Health (O.S.H.)
Instructions.
Warranty / Liability
Special Finishes (NZ) Ltd provides all the enclosed information in good faith but without warrantee and is to assist your application. However the use of this product being used is beyond their control. The manufacturers can accept no responsibility whatsoever for any damage or failure arising from its application or use. It is totally the responsibility of the user to insure that the product is suitable for its intended use.